Serial Dilution Explained: The Formula, a Worked Series and Where Errors Creep In

A rack of test tubes holding coloured liquids in the foreground of a backlit laboratory, with a technician in profile behind it holding up a tube

A serial dilution is a stepwise series in which each solution is made from the one before it, so the concentration falls by the same factor at every step. Laboratories use it to reach very low concentrations for a standard series, a concentration-response curve or a colony count. The arithmetic is simple, but errors build along the series.

This guide gives the dilution factor formula, a worked microplate table, the arithmetic of pipetting error, peptide loss to plastic, log-spaced series, and when independent dilutions suit better.

The short answer

  • Definition. A serial dilution is a sequence of dilutions in which a fixed fraction of each solution is transferred into fresh liquid to make the next one.
  • Formula. The concentration after n steps is Cn = C0 / DFn, where C0 is the starting concentration and DF is the dilution factor of each step.
  • Dilution factor. DF = (Vtransfer + Vadded) / Vtransfer, so 100 µL moved into 100 µL is a twofold dilution and 100 µL moved into 900 µL is a tenfold dilution.
  • Single steps. C1V1 = C2V2 describes one dilution, and a serial dilution is that equation applied repeatedly.
  • Errors compound. Each well inherits every error made upstream, so a small repeated bias becomes a large one by the end of a long row.
  • Peptides add a surface problem. Peptides can adsorb to tube and plate walls, and the proportional loss tends to be larger at lower concentrations, which is where the end of a series sits.

Serial dilution

Stepwise dilution · dilution series · twofold or tenfold series

Core formula
Cn = C0 / DFn
Dilution factor
(Vtransfer + Vadded) / Vtransfer
Common factors
2, about 3.16 (half-log) and 10
Main weakness
Errors carry forward from well to well
Peptide-specific risk
Adsorption to labware at low concentrations

Where the evidence stands

  1. Arithmetic settled
  2. Error propagation modelled
  3. Peptide wall loss measured
  4. Loss predictable for any given peptide

The formula is exact. How far a real series drifts depends on the liquid handler, the labware and the peptide, and should be measured rather than assumed.

The serial dilution formula and dilution factor

The dilution factor is the total volume after the transfer divided by the volume transferred. Moving 40 µL into 160 µL gives a total of 200 µL, so the factor is 200 / 40, or 5.

Factors multiply along a series. Three tenfold steps give a cumulative factor of 10 × 10 × 10, or 1,000, and the final well holds one-thousandth of the starting concentration.

How C1V1 = C2V2 fits in

The relationship C1V1 = C2V2 says the amount of analyte is unchanged by adding liquid. Moving 100 µL of a 100 µM solution to a final volume of 200 µL gives 100 × 100 = C2 × 200, so C2 is 50 µM. For one-off calculations involving molecular weight, the site’s peptide calculator handles the arithmetic.

Watch the notation. Labs usually read “1:10” as one part in ten total, which is 1 part sample plus 9 parts added liquid. Some sources read a ratio as parts to parts, where 1:10 means 11 total. State the volumes in a method.

A worked example: twofold dilution down a plate row

Take a generic standard at 100 µM and a row of eight wells in a microplate. Well 1 holds 200 µL of the standard, and wells 2 to 8 each hold 100 µL of assay buffer. Move 100 µL from well 1 to well 2, mix, take a fresh tip, then move 100 µL from well 2 to well 3, and continue along the row. Remove and discard 100 µL from well 8 so that all eight wells end at the same volume.

WellTransfers so far (n)Cumulative dilution factorNominal concentration (µM)If every step runs 2% low (µM)Random error if each step is ±1%
101100100±0.0%
2125049.00±1.0%
3242524.01±1.4%
43812.511.76±1.7%
54166.255.76±2.0%
65323.1252.82±2.2%
76641.56251.38±2.4%
871280.781250.68±2.6%

The fourth column is the serial dilution formula, Cn = 100 / 2n. The last two columns are illustrative and are explained in the next section. If an equal volume of assay reagent is later added to each well, every value here halves, so report the final in-well concentration.

The same logic for colony counts

In microbiology, a tenfold series thins a culture until one plate carries a countable number of colonies. An American Society for Microbiology method advises selecting the plate with 30 to 300 colonies [1], though recommended windows vary: a study of plating accuracy lists ranges including 25–250 and 15–300, and reports that ISO 7218 lowered the lower limit to 10 colonies per plate [2].

If a plate from the 10−5 dilution receives 100 µL and grows 42 colonies, the undiluted sample held about 42 / 10−5, or 4.2 × 106 colony-forming units (CFU), per 100 µL.

How error builds along a serial dilution

Pipetting error comes in two kinds, which is why the ISO 8655-6 gravimetric procedure evaluates systematic error and random error as separate results [3].

Random error grows slowly. A concentration at step n is the stock multiplied by n transfer ratios. The law of propagation of uncertainty combines independent contributions as a sum of variances [4], and for a product of ratios that means relative variances add. If each step carries an independent relative error u, the relative error after n steps is u × √n. At ±1% per step, seven transfers give ±2.6%.

Systematic error grows quickly. A bias repeats in the same direction at every step, so it multiplies. If every transfer ratio runs 2% low, the concentration after n steps is 0.98n of nominal. After seven transfers that is 0.868, or 13.2% low. At 5% per step it reaches about 30% low.

How a twofold serial dilution and its error grow along a rowEight wells fade from dark to pale as concentration halves from 100 to 0.78 micromolar. Below, a chart shows that a 2 percent per-step bias reaches 13.2 percent after seven transfers, while 1 percent random error per step reaches only 2.6 percent.Twofold series, 100 µM stock100 µM50 µM25 µM12.5 µM6.25 µM3.125 µM1.5625 µM0.78125 µM0%5%10%15%01234567Transfers from the stock (n)Bias: 2% low per step gives 13.2% lowRandom: ±1% per step gives ±2.6%
Illustrative arithmetic, not measured data: a repeated bias accumulates steadily along a short series, while independent random error grows with the square root of the number of transfers.

What the published modelling shows

Hanson, Ekins and Chodera modelled an eight-point, 1:2 tip-based series, using manufacturer specifications for the liquid handler and a measured effect in which residual liquid in washed fixed tips dilutes the sample. The concentration error grew with each step, and the relative bias reached almost −50% in the final well, with longer series approaching −100%. The bias shifted the modelled potency estimates toward weaker values by about 0.25 log10 units. Without that effect, the model’s pipetting bias averaged out, since it was assumed to be zero on average, so one repeating fault accounted for the accumulated bias [5].

Hedges derived variance estimates from a pipette’s specification alone and advised treating the resulting confidence intervals as minimum values [6].

Why colony counts tolerate this better

Plate counts are read on a logarithmic scale, and their largest error is often not the pipette. Jongenburger and colleagues found that low colony counts, which follow Poisson statistics, dominated uncertainty at low numbers, while pipetting, weighing and counting errors were small under well-controlled practice [2]. By that logic, the 42-colony plate above carries a counting error of about √42 / 42, or 15%. Martini and colleagues likewise expect compounding pipette error to be negligible with calibrated equipment, while noting that one failing O-ring can bias a column of a multichannel transfer [7]. Ben-David and Davidson’s simulations stayed within about ±0.1 log10 of reference values even with dilution errors up to 10% [8].

Assays that report on a continuous scale have less room: a 13% shift can be material for a calibration curve. Our guides to analytical method validation and Michaelis-Menten kinetics show where the concentration axis feeds into reported parameters, and a Bradford or BCA assay is a routine example of a standard series.

Mixing between steps and changing tips

Each calculation assumes the transferred aliquot has the average concentration of its well. The American Society for Microbiology method names accurate pipetting and adequate agitation of dilution tubes as the determinants of accuracy [1], and statistical models of dilution series assume homogenization at each step [9]. The Hanson model explicitly left out incomplete mixing [5], so the bias figures above do not include it.

  • Mix before the next transfer. Mix the well thoroughly by repeated aspiration or on a plate shaker, using the same method every time, and avoid foam.
  • Change tips between steps where carryover matters. The same method advises using different pipettes between dilutions to avoid carrying cells across [1]. For analytes, liquid left on the outside or inside of a tip moves from a higher concentration into a lower one, and the relative effect grows as concentrations fall.
  • Check fixed tips separately. Washed fixed tips can retain system liquid, the source of the bias in the Hanson model [5].
  • Do not assume the tip is inert. Ekins and colleagues found tip-based serial dilution gave weaker potency values than acoustic dispensing for all 14 compounds in a small data set; they suggested tip leaching but did not measure it [10].

Planning an in-vitro concentration series? Browse research peptides, priced in CAD and shipped from inside Canada.

Browse research peptides

Peptide adsorption and what the stock concentration means

Loss to tube and plate walls

Kristensen and colleagues measured three cationic membrane-active peptides (mastoparan X, melittin and magainin 2) in glass and plastic. At 1 µM in 220 µL, only 10–20% of the peptide was recovered from borosilicate glass or standard polypropylene after one hour. Adsorption occurred within seconds, and recovery rose with concentration, consistent with the walls saturating. Most relevant here, passing a 5 µM solution through successive containers took recovery close to zero after four containers [11]. A real series also lowers concentration at each step, but the repeated exposure to fresh surfaces is similar.

Protein LoBind tubes lost less peptide in that study [11], but low-bind labware is not a universal answer. Goebel-Stengel and colleagues tested radiolabelled endocrine peptides including ghrelin, GLP-1, insulin and leptin in a range of glass and plastic tubes. Recovery depended on the container, siliconization reduced it, and adding bovine serum albumin improved it [12]. Weikart and colleagues tested dye-labelled peptides at 1.5 nM: standard polypropylene recovered about 20% of epidermal growth factor while low-binding plates recovered nearly all, yet glucagon on one commercial low-bind plate did no better than on standard plastic. Those authors work for the maker of another plate in the comparison [13].

The practical message is to run a recovery check for your own peptide, labware and assay buffer before trusting the low end of a curve. Any additive must also be compatible with the assay, and pre-saturating a container can backfire because adsorbed peptide can later come off [11].

An adsorption artefact can mimic a real result. Wall loss is proportionally larger in dilute wells, so it makes the low end of a series weaker than its label. That can resemble lower potency.

Why the nominal stock concentration can mislead

Every well in a series is a multiple of the stock value, so an error in the stock scales the whole row. Peptide powders commonly hold water and counter-ions as well as peptide, which is why net peptide content and TFA or acetate salts change what a nominal concentration means. A series built on gross weight keeps correct ratios between wells but wrong absolute values.

Chemical change matters too; our guide to how peptides degrade covers the routes. A working rule, not a cited finding, is to prepare the series close to the assay.

Choosing twofold, half-log or tenfold spacing

A large factor covers more range with fewer wells, and a small factor gives finer resolution.

SeriesFactor per stepSpan across 8 wellsLowest well from 100 µMWhere it suits
Twofold2128-fold0.78 µMStandard series over a narrow range; microdilution susceptibility tests
Half-log√10, about 3.16About 3,160-foldAbout 32 nMConcentration-response curves with an unknown midpoint
Tenfold1010,000,000-fold10 pMColony counts and first-pass range finding

Twofold steps are the familiar pattern in broth microdilution, where they run through a 96-well plate [14]. Half-log spacing is easy to plan: 100 µL into about 216 µL of assay buffer. Log-spaced points suit sigmoidal curves, and the range has to reach both plateaus. Our guide on how to read a peptide study covers how to weigh reported values.

Serial or independent dilutions: which to use

In a parallel or independent design, each concentration is prepared directly from the stock or from an intermediate, rather than from the previous well. The two designs fail differently.

FeatureSerial dilutionIndependent dilution
Error patternCarries forward and correlates across wellsStays with the well, and points remain independent
VolumesWorkable transfers even across a wide rangeVery small transfers at wide ranges, unless intermediates are used
Surface contactEach well’s analyte has passed through earlier labwareFewer sequential transfers
SuitsPlate counts, range finding, routine curvesCalibration standards where a drifting series would mislead

In the Hanson model, direct acoustic dispensing avoided accumulated bias but showed potency variation nearly twice that of the tip-based method [5]. A middle route is to prepare two or three independent intermediates and run short series from each, which limits how far a single error can travel. Replicate series from separate starting points also expose drift that replicate wells cannot.

What’s established and what isn’t

Reasonably well established

  • The serial dilution formula is exact arithmetic.
  • Pipetting errors compound through a series, and concentration error grows with each step in published simulations [5, 6].
  • Cationic peptides can be lost rapidly to glass and standard polypropylene at micromolar concentrations [11].

Open questions

  • How much any single peptide is lost in a given plate and assay buffer: recovery is hard to predict from general rules [13].
  • The relative contribution of tips, plates and instruments in real assay discrepancies: the Hanson model left a significant gap unexplained [5].

Sourcing peptide reagents for concentration work: notes for Canadian labs

When comparing sources of research peptides in Canada, ask for documentation that speaks to the issues above.

These catalogue peptides illustrate the properties discussed above. None of the adsorption studies cited here tested them, so recovery would need its own check.

Independent testingJanoshik Analytical certificates, listed by batch on our Lab Testing page.
Check your batchMatch the batch number on your vial to its report.
Tracked, discreet shippingCanada-wide by Xpresspost in 3–7 days ($25 CAD), or free in 4–12 days on orders over $299.
Priced in CADShipped from inside Canada.

Research use only. Pure Peptides Canada products are laboratory reagents for in-vitro research, not for human or veterinary use. This article explains published research for education; it is not medical, dietary or dosing guidance.

Frequently asked questions

What is a serial dilution?

A serial dilution is a stepwise series of dilutions in which each solution is made from the previous one. Because the same factor applies at each step, the concentration falls geometrically.

What is the formula for serial dilution?

The concentration after n steps is Cₙ = C₀ / DFⁿ, where C₀ is the starting concentration and DF is the dilution factor per step. For example, a 100 µM solution after three twofold steps is 100 / 8, or 12.5 µM.

How do you calculate the dilution factor?

Divide the total volume after the transfer by the volume transferred. Moving 100 µL into 900 µL gives a total of 1,000 µL, so the dilution factor is 10. The same dilution is often written as 1:10 or 10⁻¹.

What is the difference between a twofold and a tenfold dilution?

A twofold dilution halves the concentration at each step, and a tenfold dilution reduces it to one-tenth. Twofold series give finer spacing, while tenfold series cover a wider range in few steps.

Why do errors grow in a serial dilution?

Each well is made from the previous well, so it inherits all upstream errors. Independent random errors grow roughly with the square root of the number of steps, while a repeating bias multiplies: a transfer ratio 2% low at each of seven steps leaves the last well about 13% low.

Browse peptide reagents for your next in-vitro series

Pure Peptides Canada is a Canadian-owned supplier based in Toronto that sells laboratory research reagents online in CAD. Orders ship tracked from inside Canada, and you can pay by credit or debit card, Interac e-Transfer or cryptocurrency at checkout.

References

  1. Reynolds J. Serial dilution protocols. American Society for Microbiology; 2005. Archived copy
  2. Jongenburger I, Reij MW, Boer EPJ, Gorris LGM, Zwietering MH. Factors influencing the accuracy of the plating method used to enumerate low numbers of viable micro-organisms in food. Int J Food Microbiol. 2010;143(1-2):32-40. Repository copy
  3. ISO 8655-6:2022. Piston-operated volumetric apparatus, Part 6: Gravimetric reference measurement procedure for the determination of volume. International Organization for Standardization. Table of contents
  4. NIST Technical Note 1297, Appendix A: Law of propagation of uncertainty. National Institute of Standards and Technology. NIST
  5. Hanson SM, Ekins S, Chodera JD. Modeling error in experimental assays using the bootstrap principle: understanding discrepancies between assays using different dispensing technologies. J Comput Aided Mol Des. 2015;29(12):1073-1086. DOI
  6. Hedges AJ. Estimating the precision of serial dilutions and viable bacterial counts. Int J Food Microbiol. 2002;76(3):207-214. Record
  7. Martini KM, Boddu SS, Nemenman I, Vega N. Maximum likelihood estimators for colony forming units. bioRxiv preprint. 2023. DOI
  8. Ben-David A, Davidson CE. Estimation method for serial dilution experiments. J Microbiol Methods. 2014;107:214-221. DOI
  9. Christen JA, Parker AE. Systematic statistical analysis of microbial data from dilution series. arXiv preprint. 2020. arXiv
  10. Ekins S, Olechno J, Williams AJ. Dispensing processes impact apparent biological activity as determined by computational and statistical analyses. PLoS One. 2013;8(5):e62325. DOI
  11. Kristensen K, Henriksen JR, Andresen TL. Adsorption of cationic peptides to solid surfaces of glass and plastic. PLoS One. 2015;10(5):e0122419. DOI
  12. Goebel-Stengel M, Stengel A, Taché Y, Reeve JR Jr. The importance of using the optimal plasticware and glassware in studies involving peptides. Anal Biochem. 2011;414(1):38-46. DOI
  13. Weikart CM, Breeland AP, Taha AH, Maurer BR. Enhanced recovery of low concentration protein and peptide solutions on ultra-low binding microplates. Future Sci OA. 2019;5(2):FSO367. DOI
  14. Balouiri M, Sadiki M, Ibnsouda SK. Methods for in vitro evaluating antimicrobial activity: a review. J Pharm Anal. 2016;6(2):71-79. DOI
  15. Choi KYG, Mookherjee N. Multiple immune-modulatory functions of cathelicidin host defense peptides. Front Immunol. 2012;3:149. DOI

For laboratory research use only. Not for human or veterinary use. This article summarizes published research for educational purposes and is not medical advice.